TPS(Fonics 3D-Rtps Plan)


Line products :


CQL/3D-RTPS-A: Apply to the linear accelerator、cobalt-60, use x-ray,γ-ray, including routine and conformal radiation therapy functions.

CQL/3D-RTPS-B: Apply to the linear accelerator, use x-ray, electron beam, including routine and conformal radiation therapy functions.

CQL/3D-RTPS-C: Apply to the linear accelerator、cobalt-60, use x-ray,γ-ray, electron beam, including routine , conformal and intensity modulated radiation therapy functions.


Functions :

CQL/3D-RTPS-A
  Apply to linear accelerator,cobalt-60, adopt x-ray ,gamma ray, fullwith regular and conformal functions。

CQL/3D-RTPS-B
  Apply to linear accelerator , adopt x-ray ,electron beam , fullfil regular ,conformal, functions。

CQL/3D-RTPS-C
  Apply to linear accelerator , cobalt-60,adopt x-ray ,gamma ray, electron beam , fullfil regular ,conformal, intensity modulation functions。


Functions :

CT\MRI optical impression data input by DICOM3.0 or scanner

Supply arbitrary section dissection image、DRR、BEV、REV and image from arbitrary direction

3D Image reconstruction display by transparent、semitransparent and wire frame.

 Automatic and manual drive sketch the surface of body , tumor, organ profile; extract the boundary of outline fast and exact.

Suppy SAD and SSD radiation modality; supply conformal plan、intensity modulated radiation therapy design and dose calculation

Flexible to show the relationship among beam, body and target. The user can easily view isodose line and target isodose of any point of a relatively dose, the absolute dose, isodose arbitrary section in space.

Adopt international advanced dose algorithm model, accurately calculate the dose distribution of X-ray、γray and electron beam.,with the body curved surface, organizational density dose distribution correction functions

Features :

Compared with the American Association of Medical Physics (AAMP) and The US National Canser Institute(NIC ECWG),the standard test error of X ray 、gamma ray, electron beam 3 dimensional dose algorithm is less than 1% and 2%.

The interface of this software was terse, friendly and can be used flexibly and conveniently with steady and safe in motion. 3. Precise positioning,

dimensional image accurate reconstruction, the target dose accurate algorithm

Supply rapid intensity modulated radiation therapy to reduce the MLC subfield amount,plan time and treatment time

The optimization reversal plan is fast and efficient

Apply to kinds of MLC

Support to set-up local-area network(LAN)